Help Topics
ECBASEPLATE - Column Base Plate Pinned Design

This part of the user manual describes how to use ECBASEPLATE for the design of a pinned column base plate to British Standard (BS 5950). The base plate carries the axial force (compression or tension) and the shear force of the column; no moment is transferred. ECPlus applications are designed as wizard type which is a step by step guided input procedure. If you are new to ECPlus applications, click here for general guidance.
Prerequisites: The user is expected to have a basic understanding of steel connection and base plate design concepts.
The minimum input data required to use this application is as follows:
- ❶ Column Section, Base Plate and Holding Down Bolt Details
- ❷ Bolt Anchorage Details
- ❸ Design Axial and Shear Forces
Column
This page allows to enter the column section and the weld between the column and the base plate.
TypesSelect the type of the column section.
▽ Standard
Select a standard rolled section from the steel section table. The section properties are taken from the table and cannot be edited.
▽ I Sec - User
Enter the dimensions of a user defined I section.
▽ RHS - User
Enter the dimensions of a user defined rectangular hollow section.
▽ SHS - User
Enter the dimensions of a user defined square hollow section.
With the Type Standard , displays the selected standard section. Click the button to choose another section. With a user defined Type, enter a name for the section (up to 10 characters).
Depth - D, Width - B, Flange Thickness - T, Web Thickness - tWith the Type Standard , these dimensions are displayed from the section table and are read only.
Steel Section Table
With the Type Standard , click the button. A pop-up dialog box displays a list of standard sections based on the options Section Table and Cross Section . Select a row and click Select.
▽ Section TableSelect the section database, for example British, European or AISC sections.
▽ Cross SectionSelect the section family such as UB, UC, IPE, HE, W, M, etc., based on the selection in the Section Table menu.
FilterEnter part of a section name to filter the list of sections shown for the selected Section Table and Cross Section .
I Sec - User
With the Type I Sec - User , enter the cross-sectional dimensions of the I section.
Depth - DEnter the overall depth of the section.
↔ Range: 50 to 1500 mm
Enter the flange width of the section.
↔ Range: 50 to 1500 mm
Enter the flange thickness of the section.
↔ Range: 3 to 100 mm
Enter the web thickness of the section.
↔ Range: 2 to 100 mm
RHS - User
With the Type RHS - User , enter the cross-sectional dimensions of the rectangular hollow section.
Depth - DEnter the overall depth of the section.
↔ Range: 50 to 1500 mm
Enter the overall width of the section.
↔ Range: 50 to 1500 mm
Enter the wall thickness of the section.
↔ Range: 2 to 100 mm
SHS - User
With the Type SHS - User , enter the cross-sectional dimensions of the square hollow section.
Depth - DEnter the overall size of the section.
↔ Range: 50 to 1500 mm
Enter the wall thickness of the section.
↔ Range: 2 to 100 mm
Weld
Member - Base Plate Weld Size - sEnter the leg length of the fillet weld between the column and the base plate.
↔ Range: ≥ 0 mm
- Note: A warning is shown when the weld size is more than the connected thickness less 2 mm (flange thickness T and web thickness t for an I section, member thickness t for RHS / SHS).
Base Plate & Bolts
This page allows to enter the base plate dimensions and the holding down bolt arrangement.

Base Plate
Depth - DplEnter the depth of the base plate.
↔ Range: 200 to 2000 mm
Enter the width of the base plate.
↔ Range: 200 to 2000 mm
Enter the thickness of the base plate.
↔ Range: 3 to 150 mm
Holding Down Bolts
Bolt Size - dSelect the bolt size.
▽ M12, M16, M20, M22, M24, M27, M30, M33, M36, M39, M42, M45, M48
Select the number of bolts. The bolts are placed in two rows.
▽ 4, 6, 8, 10, 12, 14
Enter the distance between the outer bolts of a row, measured along the base plate depth.
↔ Range: ≥ 0 mm
Enter the distance between the two bolt rows, measured along the base plate width.
↔ Range: ≥ 0 mm
Displays the edge distance of the bolts, ex = (Dpl - sg) / 2. This value is calculated and read only.
Bolt Anchorage
This page allows to enter the anchorage of the holding down bolts.

☉ Bolt with Plates
Choose this option when each bolt is anchored with a square anchor plate. The anchorage capacity is calculated from the embedment and the anchor plate.
☉ Others Bolts
Choose this option to enter the tension and shear anchorage capacity of each bolt directly.
Bolt with Plates

☐ Use default anchor dimensions based on bolt dia
Check this option to take the embedment, the anchor plate width and the anchor plate thickness from the bolt size. The three fields are then read only. Clear it to enter your own values.
Enter the embedment of the anchor plate in the concrete.
↔ Range: 200 to 1500 mm
Enter the width of the square anchor plate. It must not be less than 60 mm.
↔ Range: ≥ 0 mm
Enter the thickness of the anchor plate.
↔ Range: 3 to 50 mm
Shown only when Pull Out in Bolt Property is Shear. Enter the cover to the top reinforcement.
↔ Range: 20 to 70 mm
Others Bolts

Capacity
Anchorage Capacity - Tension Per Bolt - PaEnter the tension capacity of the anchorage of one bolt.
↔ Range: 0 to 1000 kN
Enter the shear capacity of the anchorage of one bolt.
↔ Range: 0 to 1000 kN
Design Loads
This page allows to enter the factored design forces at the column base.
Design Axial Force - AcEnter the design axial force. A negative (-) value indicates tension.
↔ Range: -15000 to 15000 kN
Enter the resultant design shear force, Fsv = √(Fx2 + Fy2).
↔ Range: 0 to 15000 kN
Design Settings
The steel grades, the bolt property and the concrete property are set in the pop-ups opened from the summary panels Steel Grade, Bolt Property and Concrete Property below the left navigation.
Steel Grade
Column Steel Grade - fycSelect the steel grade of the column.
▽ S 275, S 355, S 460
Select the steel grade of the base plate.
▽ S 275, S 355, S 460
Select the steel grade of the anchor plates. Shown only for Bolt with Plates.
▽ S 275, S 355, S 460
Bolt Property
Bolt Grade - fbSelect the bolt grade.
▽ 4.6, 8.8
Select how the pull out resistance of the bolt anchorage is checked in the concrete.
▽ Tension
Based on the tensile strength of concrete fs.
▽ Shear
Based on the shear strength of concrete vc. The cover to top reinforcement C is then asked on the Bolt Anchorage page.
Concrete Property
Characteristic Strength of Concrete - fcuSelect the characteristic cube strength of the foundation concrete.
▽ 10, 15, 20, 25, 30, 35, 40, 45, 50 N/mm2
Shown when Pull Out is Tension. Enter the tensile strength of concrete. It must not exceed 0.7 √fcu.
↔ Range: ≥ 0.01 N/mm2
Enter the coefficient of friction between the base plate and the bedding.
↔ Range: 0 to 1
Select the electrode classification of the weld.
▽ 35, 42, 50
Shear Strength of Concrete - vcShown when Pull Out is Shear, in place of the tensile strength. Enter the shear strength of concrete.
↔ Range: 0.01 to 4 N/mm2
Error Handling
Errors and Warnings are generated to prevent any inadvertent error in the input data. This section describes how to handle the errors and warnings. These errors are displayed at the bottom of the input page when the data in one or more input fields invalidate each other.
- Note: Out of range errors are displayed next to the input field.
| # | Error | Reason | Solution |
|---|---|---|---|
| 1 | Warning : The bolts lie at an angle greater than 45 degrees of line drawn from the outer edge of column flange | The outer bolts lie between 45 and 50 degrees from a line drawn from the outer edge of the column flange. | Reduce the bolt span or increase the base plate depth so that the bolts lie within 45 degrees. |
| 2 | Warning : Flange - Base Plate Weld Size should not exceed 3 mm (or T - 2 mm) | For an I section, the weld size s is more than the flange thickness T less 2 mm. The limit shown is 3 mm when T - 2 is less than 3 mm. | Reduce the weld size to the limit shown, or use a thicker flange. |
| 3 | Warning : Web - Base Plate Weld Size should not exceed 3 mm (or t - 2 mm) | For an I section, the weld size s is more than the web thickness t less 2 mm. The limit shown is 3 mm when t - 2 is less than 3 mm. | Reduce the weld size to the limit shown, or use a thicker web. |
| 4 | Warning : Member - Base Plate Weld Size should not exceed 3 mm (or t - 2 mm) | For an RHS / SHS, the weld size s is more than the member thickness t less 2 mm. The limit shown is 3 mm when t - 2 is less than 3 mm. | Reduce the weld size to the limit shown, or use a thicker member. |
| 5 | Error : Section Depth (D) must be less than Base Plate Depth (Dpl) | The depth of the section is equal to or greater than the depth of the base plate. | Increase the depth of the base plate or decrease the depth of the section. |
| 6 | Error : Section Depth (D) must be greater than 200 | The base plate depth Dpl is less than 200 mm. | Provide a base plate depth of at least 200 mm. |
| 7 | Error : Section Width (B) must be less than Base Plate Width (Bpl) | For an I section or RHS, the width of the section is equal to or greater than the width of the base plate. | Increase the width of the base plate or decrease the width of the section. |
| 8 | Error : Section Width (B) must be greater than 200 | The base plate width Bpl is less than 200 mm. | Provide a base plate width of at least 200 mm. |
| 9 | Error : Bolt Span cannot be negative | A negative value is entered for the bolt span. | Enter a positive value for the bolt span. |
| 10 | Error : Minimum gauge for successive bolts should be 5 times bolt diameter | The spacing between successive bolts in a row, sg / (Nb / 2 - 1), is less than 5 times the bolt diameter. | Increase the bolt span, reduce the number of bolts or use a smaller bolt size. |
| 11 | Error : The base plate is not wide enough to accommodate specified number of bolts | The bolt span plus 2 d is not less than Dpl, or the bolt cross center plus 2 d is not less than Bpl. | Increase the base plate size or reduce the bolt span / cross center. |
| 12 | Error : The bolts must lie within a line drawn at 50 degrees from the outer edge of the column flange | The outer bolts lie more than 50 degrees from a line drawn from the outer edge of the column flange. | Reduce the bolt span or increase the base plate depth. |
| 13 | Error : There is a clash between the bolt nuts and the column web | The bolt nuts overlap the column web. | Change the bolt cross center or the bolt size so that the nuts clear the web. |
| 14 | Error : Insufficient clearance between bolt and web | The clearance between the bolts and the column web is not enough. | Change the bolt cross center or the bolt size to give more clearance to the web. |
| 15 | Error : Vertical edge distance is less than the minimum allowable (1.5 * d), Hence decrease the bolt spacing | The edge distance along the base plate depth is less than 1.5 times the bolt diameter. | Decrease the bolt span or increase the base plate depth. |
| 16 | Error : Horizontal edge distance is less than the minimum allowable (1.5 * d), Hence decrease the bolt spacing | The edge distance along the base plate width is less than 1.5 times the bolt diameter. | Decrease the bolt cross center or increase the base plate width. |
| 17 | Error : There is a clash between the bolt nuts and the column flange | The bolt nuts overlap the column flange. | Change the bolt span or the bolt size so that the nuts clear the flange. |
| 18 | Error : The bolts lie beyond the column section center | The bolts are located beyond the center of the column section. | Change the bolt span / cross center so that the bolts lie on their own side of the section center. |
| 19 | Error : Bolts cannot lie inside the column flange | The bolts are located inside the column flange. | Change the bolt span / cross center so that the bolts lie clear of the flange. |
| 20 | Error : Insufficient clearance between bolt and flange | The clearance between the bolts and the column flange is not enough. | Change the bolt span or the bolt size to give more clearance to the flange. |
| 21 | Error : Bolts cannot lie beyond column flange. | For an I section, the bolt span sg is equal to or greater than the section depth D. | Reduce the bolt span to less than the section depth. |
| 22 | Error : There is a clash between adjacent anchor plates | For Bolt with Plates, the anchor plate width ba is equal to or greater than the bolt gauge or the bolt cross center. | Reduce the anchor plate width or increase the bolt spacing. |
| 23 | Error : Anchor plate length cannot be less than 60 mm | For Bolt with Plates, the anchor plate width ba is less than 60 mm. | Provide an anchor plate width of at least 60 mm. |
| 24 | Error : Tensile strength of concrete cannot be greater than 0.7 * √(fcu) | The tensile strength of concrete fs is more than 0.7 √fcu. | Reduce the tensile strength of concrete or select a higher concrete grade. |